Set Service Configuration
更新时间: 2026/08/06
在Gitcode上查看源码

Set Service Configuration

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to set the service configuration.

Privilege

SecurityMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 0Fh
5Service ID. See Table 1.
6Service parameter. For details, see Table 2.
7[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
8Offset, indicating the offset of the written data. The value starts from 0.
Write data in sequence when they are written as multiple frames.
9Length: indicates the length of the written data.
10:NWritten data

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the SSH port number to 22.

Request:

bash
ipmitool raw 0x30 0x93 0xDB 0x07 0x00 0x0f 0x02 0x02 0x00 0x00 0x00 0x01 0x16 0x00

Response:

text
 db 07 00

Back to Index