Set Web Auth Code
更新时间: 2026/08/06
在Gitcode上查看源码

Set Web Auth Code

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Set the web authentication code.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 0Bh
5End of List, indicating whether the current data is complete.
Set multiple times if the data amount is large.
Indicates whether the data transmission is complete.
[7:1]: User Privilege
3=operator
4=administrator
[0]: End of list
0=last data
1=middle data
6Offset: indicates the offset of the authentication code. The value is 0 Base.
7Length: length of the transferred data.
8:NData

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Obtain the highest event severity of sensor 0.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index