Get Sensor Max Event Severity
更新时间: 2026/08/06
在Gitcode上查看源码

Get Sensor Max Event Severity

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This API is used to obtain the highest event severity of a sensor.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=09h
5Sensor Number

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Event Severity
0h=No State Assert Event
1h=Non Critical
2h=Critical
3h=Non Recoverable
Other=Reserved

Command Example

Obtain the highest event severity of sensor 0.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN