Set Mgnt Configuration Recover Point
更新时间: 2026/08/06
在Gitcode上查看源码

Set Mgnt Configuration Recover Point

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to set the management configuration recovery point.

Privilege

UserMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD93h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=07h
5Recover Point Selector
0h=Backup point 1
6Action
0xAA Start Mgnt Configuration backup.
0x55 Get backup status

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Backup progress
[7:4]-reserved
[3:0]-Backup progress
0h=Backup in progress
1h=Backup completed

Command Example

Set the management configuration recovery point.

Request:

bash
ipmicmd -k "0f 00 30 93 db 07 00 07 00 aa" smi 0

Response:

text
0f 31 00 93 00 db 07 00 01

Back to Index