Set Mgnt Configuration Recover Point
更新时间: 2026/08/06
在Gitcode上查看源码Set Mgnt Configuration Recover Point
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to set the management configuration recovery point.
Privilege
UserMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=07h |
| 5 | Recover Point Selector 0h=Backup point 1 |
| 6 | Action 0xAA Start Mgnt Configuration backup. 0x55 Get backup status |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Backup progress [7:4]-reserved [3:0]-Backup progress 0h=Backup in progress 1h=Backup completed |
Command Example
Set the management configuration recovery point.
Request:
bash
ipmicmd -k "0f 00 30 93 db 07 00 07 00 aa" smi 0Response:
text
0f 31 00 93 00 db 07 00 01