Send Trap Event
更新时间: 2026/08/06
在Gitcode上查看源码Send Trap Event
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Events are sent in trap mode.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 93h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=01h |
| 5 | Channel number. (This value is required to select which configuration parameters are to be used to send the Alert.) [7:4]-reserved [3:0]-Channel number |
| 6 | Destination Selector [7:4]-reserved [3:0]-destination selector. Selects which alert destination should go to. |
| 7 | Generator ID_L |
| 8 | Generator ID_H |
| 9 | EvMRev |
| 10 | Sensor Type |
| 11 | Sensor # |
| 12 | Event Dir | Event Type |
| 13 | Event Data 1 |
| 14 | Event Data 2 |
| 15 | Event Data 3 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Send a trap event.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN