Set System Parameters
更新时间: 2026/08/06
在Gitcode上查看源码

Set System Parameters

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Setting system parameters

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=6Dh
5Parameter selector. For details, see Table 1.
6[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
7:8Write Offset: offset of the data written by LS Byte first. The value starts from 0. If the data is long and needs to be written for multiple times, the data must be written in sequence from the beginning to the end.
9Length: length N of the data to be written this time
10:9+NParameter data. The data varies according to the Parameter Selector parameter. For details, see Table 1.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Example

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 6D \{selector\} \{end\of\list\} \{offset\} \{length\} \{data\}" smi 0

Response:

text

Back to Index