Set System Parameters
更新时间: 2026/08/06
在Gitcode上查看源码Set System Parameters
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Setting system parameters
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=6Dh |
| 5 | Parameter selector. For details, see Table 1. |
| 6 | [7:1]: reserved [0]: cascading flag 0: last data 1: middle data |
| 7:8 | Write Offset: offset of the data written by LS Byte first. The value starts from 0. If the data is long and needs to be written for multiple times, the data must be written in sequence from the beginning to the end. |
| 9 | Length: length N of the data to be written this time |
| 10:9+N | Parameter data. The data varies according to the Parameter Selector parameter. For details, see Table 1. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Example
Request:
bash
ipmicmd -k "0f 00 30 92 db 07 00 6D \{selector\} \{end\of\list\} \{offset\} \{length\} \{data\}" smi 0Response:
text