Set Power Capping Attribute
更新时间: 2026/08/06
在Gitcode上查看源码

Set Power Capping Attribute

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

The IMU reports the power capping triggering status to the BMC.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=67h
5Parameter. For details, see Table 1.
6Length: length of the written data
7:NDatas: data to be written

Response Information

ByteData Field
1Completion Code
2Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Table 1 Power capping parameters

Parameter#Parameter Data
Power Capping Triggering0x01data1: power capping triggering status
0- The power capping is canceled.
1- Power capping is triggered.

Command Example

Set the power capping status.

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 67 01 01 01" smi 0

Response:

text
0f db 07 00

Back to Index