Set Power Capping Attribute
更新时间: 2026/08/06
在Gitcode上查看源码Set Power Capping Attribute
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
The IMU reports the power capping triggering status to the BMC.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=67h |
| 5 | Parameter. For details, see Table 1. |
| 6 | Length: length of the written data |
| 7:N | Datas: data to be written |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Table 1 Power capping parameters
| Parameter | # | Parameter Data |
|---|---|---|
| Power Capping Triggering | 0x01 | data1: power capping triggering status 0- The power capping is canceled. 1- Power capping is triggered. |
Command Example
Set the power capping status.
Request:
bash
ipmicmd -k "0f 00 30 92 db 07 00 67 01 01 01" smi 0Response:
text
0f db 07 00