Report 80 Port Info
更新时间: 2026/08/07
在Gitcode上查看源码Report 80 Port Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2026/08/07 | Initial draft: add command details |
Basic Information
Function Description
Receives port 80 information reported by the BIOS.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=63h |
| 5:N | Port 80 information reported by the BIOS. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
The BIOS reports port 80 information.
Request:
bash
ipmicmd -k "0f 00 30 92 db 07 00 63" smi 0Response:
text
0f 31 00 92 00 db 07 00