Basic Information

Function Description

Set the SMBIOS information (device information in Region Type I).

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=5Bh
5BIOS ID: This parameter is reserved for multi-host scenarios. In single-host scenarios, this parameter has a fixed value of 0.
6Type of the obtained information: (The number is in decimal format.)
1: Smbios Version
2: Smbios SKUNumber (SKUNumber)
3: Smbios Family
7Length N
8:7+NContent

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN