代码仓
中
Get TPCM Measurement Status
更新时间: 2026/08/06
在AtomGit上查看源码

Get TPCM Measurement Status ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtains the TPCM measurement switch value.

Privilege ​

UserMgmt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=59h
5Firmware Type
0: measurement initiated by the BIOS
1: measurement initiated by the SHIM side
2: measurement initiated by the GRUB
6Firmware Detail Type
Firmware Type:0
0: measurement initiated by the BIOS
1: reserved1
2: reserved2
Firmware Type:1
0: measurement initiated by the SHIM
1: reserved1
2: reserved2
Firmware Type:2
0: grub.cfg
1: kernel
2: initrd

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Action type
1: measure enable & control enable
2: measure disable
3: measure enable & control disable

Command Example ​

Request:

bash
ipmitool raw 0x30 0x92 0xdb 0x07 0x00 0x59 0x00 0x00

Response:

text
db 07 00 01

Back to Index ​