Get Host Digest Result ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Obtains the measurement result of each firmware on the host.

Privilege ​

UserMgmt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=58h
5Firmware Type
0: measurement initiated by the BIOS
1: measurement initiated by the SHIM side
2: measurement initiated by the GRUB
6Firmware Detail Type
Firmware Type:0
0: measurement initiated by the BIOS
1: reserved1
2: reserved2
Firmware Type:1
0: measurement initiated by the SHIM
1: reserved1
2: reserved2
Firmware Type:2
0: grub.cfg
1: kernel
2: initrd

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Control Result
1: success
2: fail

Command Example ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​