Get BCU diagnosis data
更新时间: 2026/08/06
在Gitcode上查看源码

Get BCU diagnosis data

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtains information about uncorrectable hardware faults in the OS.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand = 55h
5Reserved. The default value is 0xFF.
6End of List indicates whether the current data is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]: reserved.
[0]: End of list.
0=last data.
1=middle data.
7:10Length: length of the data to be stored
11:14Offset of the LSB First data segment relative to the start position of the file
15:16Checksum, CRC16
17:NData

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Obtain information about uncorrectable hardware faults in the OS.

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 55 ff 00 06 00 00 00 00 00 00 00 f4 2e 31 32 33 34 35 36" smi 0

Response:

text
0f 31 00 92 00 db 07 00

Back to Index