Set BIOS Firmware Version
更新时间: 2026/08/06
在Gitcode上查看源码

Set BIOS Firmware Version

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Set the BIOS firmware version.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=53h
5BIOS type parameters
0x00: compute blade I/O die BIOS
Other values are reserved.
6:NIndicates the version string that contains a maximum of 21 bytes.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index