代码仓
中
Get BMC Two Factor Auth State
更新时间: 2026/08/06
在AtomGit上查看源码

Get BMC Two Factor Auth State ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

The BIOS reads the BMC two-factor certificate status.

Privilege ​

SecurityMgmt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=51h

Response Information ​

ByteData Field
1Completion Code
Generic codes, plus following command-specific completion code(s):
80h=parameter not supported
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Whether two-factor authentication is enabled. The value can be MutualAuthenticationState.
6Whether OCSP check is enabled for two-factor authentication (MutualAuthenticationOCSP)

Command Example ​

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 51" smi 0

Response:

text
0f 00 db 07 00 00 00

Back to Index ​