Set Smart Provisioning Info
更新时间: 2026/08/06
在Gitcode上查看源码

Set Smart Provisioning Info

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets SP information in the BIOS.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=4Dh
5BIOS ID: This parameter is reserved for multi-host scenarios. In single-host scenarios, this parameter has a fixed value of 0.
6Type of the set information Table 1
7Sets the message length.
8:NConfigure Merge Request

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index