Set Smart Provisioning Info
更新时间: 2026/08/06
在Gitcode上查看源码Set Smart Provisioning Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Sets SP information in the BIOS.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=4Dh |
| 5 | BIOS ID: This parameter is reserved for multi-host scenarios. In single-host scenarios, this parameter has a fixed value of 0. |
| 6 | Type of the set information Table 1 |
| 7 | Sets the message length. |
| 8:N | Configure Merge Request |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN