Get Name of BMC
更新时间: 2026/08/06
在Gitcode上查看源码

Get Name of BMC

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtaining the Out-of-Band Management Software Name

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = 45h

Response Information

ByteData Field
1Completion Code
0x00: success (0xFF indicates an unknown error)
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Length of the returned out-of-band management software name
6:NName of the out-of-band management software obtained from the BMC

Interconnected Component

[BIOS][Equipment][SMM]

Command Example

Identify the chassis.

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 45" smi 0

Response:

text
0f 31 00 92 00 db 07 00 04 69 42 4d 43

Back to Index