Get Name of BMC
更新时间: 2026/08/06
在Gitcode上查看源码Get Name of BMC
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtaining the Out-of-Band Management Software Name
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 45h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 0x00: success (0xFF indicates an unknown error) |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Length of the returned out-of-band management software name |
| 6:N | Name of the out-of-band management software obtained from the BMC |
Interconnected Component
[BIOS][Equipment][SMM]
Command Example
Identify the chassis.
Request:
bash
ipmicmd -k "0f 00 30 92 db 07 00 45" smi 0Response:
text
0f 31 00 92 00 db 07 00 04 69 42 4d 43