Clear Memory Soft Isolation Address
更新时间: 2026/08/06
在Gitcode上查看源码

Clear Memory Soft Isolation Address

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Clears the memory soft isolation address.

Privilege

DiagnoseMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=39h
5[7]: command response mode
0- synchronous. The BMC has a return value, and the response needs to be parsed.
[6]: clearance mode
1- Clear the specified memory.
0- Clear all
[5:0]: segment, 1-based. For high-performance servers such as 9032, each segment indicates a 4-socket partition. The BDF is numbered in the 4-socket system. To be compatible with earlier products and facilitate unified BMC management, the 8100 and other 4-socket or lower-socket systems do not need to distinguish BDFs by segment. Therefore, the segment is always 0.
6CPU ID, reserved. It is valid when bit 6 of byte 5 is set to 1.
7Channel ID, reserved. It is valid when bit 6 of byte 5 is set to 1.
8DIMM ID, reserved. It is valid when bit 6 of byte 5 is set to 1.
9:17Reserved field. The default value is 0.

Response Information

ByteData Field
1Completion Code
d6- indicates that the command is not registered with the BMC and is not supported.
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Clear all memory soft isolation addresses.

Request:

bash
ipmicmd -k "0f 00 30 92 db 07 00 39 00 00 00 00" smi 0

Response:

text
0f 31 00 92 00 db 07 00