Get NetCard Port Status
更新时间: 2026/08/06
在Gitcode上查看源码

Get NetCard Port Status

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to obtain the LOM port status.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=29h
5NetCard Type
Network adapter type
1: LOM NCSI TYPE, indicates that the LOM is integrated with the mainboard.
5: LOM2 NCSI TYPE, onboard NIC daughter card. The NIC is an independent card.
9: mezz (reserved)
6NIC location: slot ID. If the value of NetCard Type is 1, this parameter is invalid. The default value is 0.
7Port ID

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Status
0: disabled
1: enabled

Command Example

Obtain the LOM status whose port ID is 1.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index