Function Description

Create a link to the USB storage device.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=25h
5Parameter Selector, parameter selection=00h
00h: Create USB Mass Storage
03h: Close USB Mass Storage
6Location:
0: local USB flash drive (The internal flash memory of the BMC is virtualized as a USB flash drive.)
7type:
0: temporary mounting (In temporary mounting, x86 only reads the USB flash drive, and the BMC can also read and write the USB flash drive.)
1: formal mounting (During formal mounting, the x86 can read and write the USB flash drive, but the BMC cannot access the USB flash drive.)
8device id:
0: iBMA USB flash drive
1: SP USB flash drive
NOTE: To be compatible with earlier versions, this byte is not mandatory. If this byte is unavailable, the operation can be performed only on the SP USB flash drive.

Response Information

ByteData Field
1Completion Code
NOTE: For a long-delay IPMI command, the returned value does not indicate the operation result. You can query the operation result by running the Get USB Mass Storage Status command with the parameter set to 01h.For the SP USB flash drive, an error code (error code = 0xCE) is returned for the request after the non-system interface or BIOS startup is complete.For an iBMA USB flash drive, an error code 0xCE is returned if the system is powered off or the BIOS startup is not complete.When the USB port is used by other devices, an error code (error code = 0xC1) is returned.If there is no iBMA partition or no iBMA installation package, an error is returned (error code = 0xD5).
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5reserved

Command Example

Query the heat dissipation mode.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN