21h — Get Fault Diagnostic Information ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft, add command details

Basic Information ​

Function Description ​

Queries fault diagnostic information.

Privilege ​

DiagnoseMgnt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS byte first. Fixed length of 3 bytes. For example, if the manufacturer ID is 2011, the hexadecimal value is 0x0007DB, where byte 1 = DBh, byte 2 = 07h, byte 3 = 00h.
4Sub command = 21h (newly defined, replacing 19h).
5Parameter Selector, see Table 1.

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS byte first. Fixed length of 3 bytes. For example, if the manufacturer ID is 2011, the hexadecimal value is 0x0007DB, where byte 1 = DBh, byte 2 = 07h, byte 3 = 00h.
5:NData. See Table 1 for specific return data format.

Command Examples ​

Get Fault Diagnostic Information ​

Request:

ipmicmd -k "0f 00 30 94 db 07 00 21 00" smi 0

Response:

0f 31 00 94 d6