Set FDM errinfo
更新时间: 2026/08/06
在Gitcode上查看源码Set FDM errinfo
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to report FDM error information.
Privilege
DiagnoseMgnt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=18h |
| 5 | Domain (AER-10h; MCA-11h; Mem-12h) |
| 6 | Sub Mode Domain == AER 00h-Coherent Interface Local Error Reporting Register(IRP: Integrated Coherent Interface) 01h-IIO Core Local Error Reporting Registers 02h-Miscellaneous Local Error Reporting Registers 03h-Intel® VT-d Local Error Reporting Registers 04h-DMA 05h-DMI 06h-PCIe Additional Error Reporting Registers 07h-PCIe Error Reporting Registers Domain == MCA 00 Domain == MEM 00 |
| 7:N | ErrData |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Report memory error information.
Request:
bash
ipmicmd -k "0f 00 30 92 db 07 00 18 10 00 01" smi 0Response:
text
0f db 07 00