Get System Information
更新时间: 2026/08/06
在Gitcode上查看源码

Get System Information

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

This command is used to query the in-band information of the system, such as the CPU usage, memory usage, and disk usage threshold.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=16h
5data1:1-access interface
1-web
2-snmp
3-BMA
6:7Indicates the read offset. The value starts from 0 (LS-byte first).
8Length: read length
9:Ndata format:
data1:1-key length
data2:N-key string

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:6Total length of the read data (in bytes), LS-byte first
7End of list, indicating whether the data reading is complete. Long data may need to be read multiple times. This field is used to check whether data is completely read.
[7:1]: reserved
[0]: End of list
0=last data
1=middle data
8:Ndata format:
data1:1-property1 length
data2:N- property1 string
......
dataN+2:1-propertyN length
dataN+3:N-propertyN string

Command Example

Query the heat dissipation mode.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index