Set thermal enforce policy
更新时间: 2026/08/06
在Gitcode上查看源码

Set thermal enforce policy

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets the heat dissipation mode.

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn30h
CMD92h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=13h
5policy option
1-Fan speed enforce
2-elevation
3-Power PreCapping to cooling
4-Temporary Fan speed enforce
5-Dft Fan speed enforce
6-Set Cooling Min Level
other reserved
6For details about the value of policy value, see Table 1.
Note: To support heat dissipation for high power consumption cards that are not included in the compatibility list, the BIOS setup menu provides the high fan speed flag.

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the heat dissipation mode.

Request:

bash
db 07 00

Response:

text
ipmitool raw 0x30 0x92 0xdb 0x07 0x00 0x13 0x01 0x10

**Response:**

Back to Index