Set Upgrade ROM SKU Number
更新时间: 2026/08/06
在Gitcode上查看源码Set Upgrade ROM SKU Number
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
SKU code when the ROM is upgraded.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 92h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand = 12h |
| 5 | SKU number: 00h no upgrade ROM (no upgrade ROM is inserted) 01h 1 02h 2 ...... 09h 9 Other Reserved |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the SKU number for ROM upgrade.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN