Set Cooling Info
更新时间: 2026/08/06
在Gitcode上查看源码

Set Cooling Info

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Set heat dissipation information.

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=27h
5:6Parameter selector. For details, see Heat Dissipation Parameters.
7Length: write length
8:NParameter Data

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Heat dissipation parameters

OverviewParameter Selectorparameter data-getparameter data-set
Heat Dissipation Medium0x0000Response:
Data5, heat dissipation medium type:
0: air cooling
1: liquid cooling
Request:
Length: 1
Data:
0: air cooling
1: liquid cooling

Command Example

Set the heat dissipation medium to air cooling.

Request:

bash
ipmitool raw 0x30 0x91 0xdb 0x07 0x00 0x27 0x00 0x00 0x01 0x00

Response:

text
db 07 00

Back to Index