Get Cooling Info
更新时间: 2026/08/06
在Gitcode上查看源码Get Cooling Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains heat dissipation information.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 91h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=27h |
| 5:6 | Parameter selector. For details, see Heat Dissipation Parameters. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | Data |
Command Example
Obtain the heat dissipation medium.
Request:
bash
ipmitool raw 0x30 0x91 0xdb 0x07 0x00 0x28 0x00 0x00Response:
text
db 07 00 00