Get Cooling Device Level
更新时间: 2026/08/06
在Gitcode上查看源码

Get Cooling Device Level

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtains the heat sink component level.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=26h
5Device Type
0: fan
1: pump
6Device Id
0-0xfe: ID of a single heat sink
0xff: all heat sink components
7Mode:
0: value set in manual mode
1: actual control value of the component

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5Device Num: N, indicating the number of heat sinks
6:N+5Heat dissipation level. If the device ID is specified, the heat dissipation level of the specified component is returned. If the device ID is 0xff, the heat dissipation levels of all specified components are returned.

Command Example

Obtain the heat dissipation levels of all fans in manual mode.

Request:

bash
ipmitool raw 0x30 0x91 0xdb 0x07 0x00 0x26 0x00 0xff 0x00

Response:

text
db 07 00 0x04 0x0a 0x0a 0x0a 0x0a

Back to Index