代码仓
中
Set Cooling Device Level
更新时间: 2026/08/06
在AtomGit上查看源码

Set Cooling Device Level ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Sets the level of the heat sink.

Privilege ​

BasicSetting

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=25h
5Device Type
0: fan
1: pump
6Device Id
0-0xfe: ID of a single heat sink
0xff: All components take effect.
7Level: 0-100, component heat dissipation level

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the heat dissipation level of all fans to 50%. ​

Request:

bash
ipmitool raw 0x30 0x91 0xdb 0x07 0x00 0x25 0x00 0xff 0x32

Response:

text
db 07 00

Back to Index ​