Set Event Severity Level
更新时间: 2026/08/06
在Gitcode上查看源码

Set Event Severity Level

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Configure the event alarm severity.

Privilege

UserMgmt

Command Information

Request Information

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. , vendor ID
4Sub command, subcommand = 21h
5:8Event ID, which corresponds to the event code.
9Level Alarm severity. The options are as follows:
00h: Normal
01h: Minor
02h: Major
03h: Critical

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example

Set the alarm severity of the event code (0x01000015) to Normal.

Request:

bash
ipmitool raw 0x30 0x91 0xDB 0x07 0x00 0x21 0x15 0x00 0x00 0x01 0x00

Response:

text
db 07 00

Back to Index