Basic Information
Function Description
Configure the event alarm severity.
Privilege
UserMgmt
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 91h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. , vendor ID |
| 4 | Sub command, subcommand = 21h |
| 5:8 | Event ID, which corresponds to the event code. |
| 9 | Level Alarm severity. The options are as follows: 00h: Normal 01h: Minor 02h: Major 03h: Critical |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the alarm severity of the event code (0x01000015) to Normal.
Request:
bash
ipmitool raw 0x30 0x91 0xDB 0x07 0x00 0x21 0x15 0x00 0x00 0x01 0x00Response:
text
db 07 00