Set Slot Extend-string
更新时间: 2026/08/06
在Gitcode上查看源码Set Slot Extend-string
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set the extended information about a specified slot.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 91h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=1Fh |
| 5 | para select 1: slot number 2: slot number + extended character string corresponding to the slot number |
| 6 | slot id (0-255): indicates the slot ID of the board, which corresponds to the slot ID of the X6000, E6000, or X8000. The value starts from 0. |
| *7:N | When para select is set to 2, this field is available. Fill in the actual length. The maximum length is 10 characters. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
Command Example
Set the extended character string of a slot.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN