Set Slot Extend-string
更新时间: 2026/08/06
在Gitcode上查看源码

Set Slot Extend-string

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Set the extended information about a specified slot.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command=1Fh
5para select
1: slot number
2: slot number + extended character string corresponding to the slot number
6slot id (0-255): indicates the slot ID of the board, which corresponds to the slot ID of the X6000, E6000, or X8000. The value starts from 0.
*7:NWhen para select is set to 2, this field is available. Fill in the actual length. The maximum length is 10 characters.

Response Information

ByteData Field
1Completion Code

Command Example

Set the extended character string of a slot.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index