代码仓
中
Set Serial Connection
更新时间: 2026/08/06
在AtomGit上查看源码

Set Serial Connection ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This command is used to set the connection direction of the serial port.

Privilege ​

BasicSetting

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD91h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4sub command=0x17
5Source serial selector. For details, see Table 1. The source serial port can only be 00h, 01h, or 02h.
6For details about the destination serial selector, see Table 1.

Response Information ​

ByteData Field
1Completion Code
00h: Successfully
80h: Connection not support
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the serial port connection information. ​

Request:

bash
ipmicmd -k "0f 00 30 91 db 07 00 17 01 00" smi 0

Response:

text
0f 31 00 91 00 db 07 00

Back to Index ​