Get Backup SEL Info
更新时间: 2026/08/06
在Gitcode上查看源码Get Backup SEL Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the information about the backup SEL.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 91h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | sub command=0x15 |
| 5 | Backup ID |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code Return an error completion code if the SEL is empty. 80h=No backup SEL record 81h=Backup SEL erase in progress. 82h=Backup SEL changed. If completion code is not 0, the following bytes is ignored. |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | Backup SEL record Format Version-version number of the SEL command set for this SEL Device. 51h for this IPMI2.0. (BCD encoded).BCD encoded with bits 7:4 holding the Least Significant digit of the revision and bits 3:0 holding the Most Significant bits. |
| 6 | Entries LS Byte-number of log entries in SEL, LS Byte |
| 7 | Entries MS Byte-number of log entries in SEL, MS Byte |
| 8:11 | Backup timestamp. LS byte first. |
Command Example
Obtain system health events.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN