Function Description

Obtains the locking system ID of multiple nodes.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn30h
CMD90h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, subcommand=75h

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5ID of the current system.
6ID of the system that is successfully locked. The value 255 indicates that no system is locked.
7Indicates the lock type. The value ranges from 0 to 1. The value 0 indicates that no type is locked.
8Indicates the lock duration. The value ranges from 0 to 255, in minutes. The value 0 indicates that no system is locked.

Command Example

The current locked system is system 1. System 2 obtains the locked system ID of multiple nodes.

Request:

bash
ipmicmd -k "0f 00 30 90 db 07 00 75" smi 0

Response:

text
 db 07 00 02 01 01 05