Get LockDown System Id of Multiple Nodes
更新时间: 2026/08/06
在Gitcode上查看源码Get LockDown System Id of Multiple Nodes
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the locking system ID of multiple nodes.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 90h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, subcommand=75h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | ID of the current system. |
| 6 | ID of the system that is successfully locked. The value 255 indicates that no system is locked. |
| 7 | Indicates the lock type. The value ranges from 0 to 1. The value 0 indicates that no type is locked. |
| 8 | Indicates the lock duration. The value ranges from 0 to 255, in minutes. The value 0 indicates that no system is locked. |
Command Example
The current locked system is system 1. System 2 obtains the locked system ID of multiple nodes.
Request:
bash
ipmicmd -k "0f 00 30 90 db 07 00 75" smi 0Response:
text
db 07 00 02 01 01 05