Erase Teeos Flash
更新时间: 2026/08/06
在Gitcode上查看源码Erase Teeos Flash
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Sets/Queries the Teeos area to be erased.
Privilege
Administrator
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 90h |
| 1 | Sub command, subcommand = 70h |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5 | 1=Erase Flash Command 2=Query Result |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | 01: The erase operation is successful. 02: The erase operation fails. 03: The erase operation is being performed. |
Command Example
Erase the SOS area.
Request:
bash
[root@localhost ~]# ipmicmd -k "0f 00 30 90 70 db 07 00 01" smi 0
0f 31 00 90 00