Set Fru E-lable MfgDateTime Length
更新时间: 2026/08/06
在Gitcode上查看源码Set Fru E-lable MfgDateTime Length
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to set the format of the MfgDateTime information read from the EEPROM. When the time information is read from the EEPROM, the 3-byte or 4-byte content is read based on the format.
This command is used only during production. By default, three bytes are read.
Privilege
Administrator
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 90h |
| 1 | Sub command, subcommand=69h |
| 2 | 0: Read the three-byte format of MfgDateTime. 1: Read the MfgDateTime four-byte format. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the production date and time byte length flag in the FRU electronic label.
Request:
bash
ipmicmd -k "0f 00 30 90 69 01" smi 0Response:
text
0f 31 00 90 00 db 07 00