代码仓
中
Set Fru E-label MfgDateTime Length
更新时间: 2026/08/06
在AtomGit上查看源码

Set Fru E-label MfgDateTime Length ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

This command is used to set the format of the MfgDateTime information read from the EEPROM. When the time information is read from the EEPROM, the 3-byte or 4-byte content is read based on the format.

This command is used only during production. By default, three bytes are read.

Privilege ​

Administrator

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD90h
1Sub command, subcommand=69h
20: Read the three-byte format of MfgDateTime.
1: Read the MfgDateTime four-byte format.

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the production date and time byte length flag in the FRU electronic label. ​

Request:

bash
ipmicmd -k "0f 00 30 90 69 01" smi 0

Response:

text
0f 31 00 90 00 db 07 00

Back to Index ​