Set DFT Mode
更新时间: 2026/08/06
在Gitcode上查看源码

Set DFT Mode

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Enables or disables the DFT command.

Privilege

DiagnoseMgnt

Command Information

Request Information

ByteData Field
NetFn30h
CMD90h
1Subcommand, subcommand=20
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
51=Enable DFT Command
0=Disable DFT Command

Response Information

ByteData Field
1Completion Code

Command Example

Enable DFT.

Request:

bash
[root@localhost ~]# ipmicmd -k "0f 00 30 90 20 db 07 00 01" smi 0

Response:

text
0f 31 00 90 00