Set DFT Mode
更新时间: 2026/08/06
在AtomGit上查看源码

Set DFT Mode ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Enables or disables the DFT command.

Privilege ​

DiagnoseMgnt

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD90h
1Subcommand, subcommand=20
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
51=Enable DFT Command
0=Disable DFT Command

Response Information ​

ByteData Field
1Completion Code

Command Example ​

Enable DFT. ​

Request:

bash
[root@localhost ~]# ipmicmd -k "0f 00 30 90 20 db 07 00 01" smi 0

Response:

text
0f 31 00 90 00