ipmcset -t storage -d ctrlconfig
更新时间: 2026/07/28
在Gitcode上查看源码Command Function
Set RAID controller configurations
Command Format
ipmcset -t storage -d ctrlconfig -v <RAID Controller ID> <[-cb <enabled|disabled>] [-smartercb <enabled|disabled>] [-jbod <enabled|disabled>] [-mode <RAID|HBA|JBOD|Mixed>] [-restore]>
Command type
ipmcset
Parameters
| Name | Type | Required | Default | Constraint | Description |
|---|---|---|---|---|---|
ControlId | number | Yes | - | Type: Range; 0, 255 | -v <RAID Controller ID> The RAID controller which will be set. It is mandatory. |
CopyBackState | - | No | - | Type: Enum; Enum: enabled, disabled, default | -cb <enabled│disabled> Set RAID controller Copyback to be enabled or disabled. enabled = Enable RAID controller Copyback disabled = Disable RAID controller Copyback |
SmarterCopyBackState | - | No | - | Type: Enum; Enum: enabled, disabled, default | -smartercb <enabled│disabled> Set RAID controller Copyback on SMART error to be enabled or disabled. It will be disabled when 'Copyback' is disabled. enabled = Enable RAID controller Copyback on SMART error. It can be enabled only when Copyback is enabled disabled = Disable RAID controller Copyback on SMART error |
JBODState | - | No | - | Type: Enum; Enum: enabled, disabled, default | -jbod <enabled│disabled> Set RAID controller JBOD to be enabled or disabled. enabled = Enable RAID controller JBOD mode disabled = Disable RAID controller JBOD mode |
WorkMode | string | No | - | Type: Enum; Enum: RAID, JBOD, HBA, Mixed, default | -mode <RAID│HBA│JBOD│Mixed> Set RAID controller working mode. |
Restore | - | No | - | - | -restore Restore RAID controller settings. It can't be specified with other options simultaneously but mode. |
Example
ipmcset -t storage -d ctrlconfig -v 0 -cb enabled -smartercb enabled -jbod enabled -mode RAIDipmcset -t storage -d ctrlconfig -v 0 -restoreOutput Examples
Set RAID controller Copyback state successfully.
Set RAID controller Copyback state on SMART error successfully.
Set RAID controller JBOD mode successfully.
Set RAID controller mode successfully.
Restore RAID controller settings successfully.